29 CFR 1926.441, 1926.404, 1926.152, 1926.153, 1926.150; 1910.106, 1910.110, 1910.151(c), 1910.132; NFPA 58 (2024)
Scissor Lift Charging and Refueling: Electric, Diesel, and Propane
How to safely charge electric scissor lifts, water batteries, handle acid spills, refuel diesel rough-terrain units, change propane on dual-fuel lifts, prevent fires, and handle damaged batteries and chargers, including required PPE.

What's covered
- 1.Scissor Lift Charging and Refueling
- 2.Charging Area Requirements
- 3.PPE for Charging and Refueling
- 4.Charging an Electric Scissor Lift
- 5.Disconnecting and Moving the Lift
- 6.Watering Batteries
- 7.Battery Acid Spills and First Aid
- 8.Refueling Diesel Scissor Lifts
- 9.Propane on Dual-Fuel Lifts
- 10.Fire and Spill Safety
- 11.Damaged Batteries and Chargers
- 12.Return to Service and Routine
Key takeaways
- Charge only in designated, ventilated areas with eyewash and an extinguisher.
- Wear goggles or a face shield, acid gloves, and an apron for battery work.
- Lower the platform before charging; unplug before driving.
- Water lead-acid batteries after charging with distilled water.
- Stop the engine before refueling; leak-check propane with solution, never flame.
- Tag out damaged batteries, chargers, and cords.
Every course includes
Professional narration, synced captions, a knowledge-check quiz, completion records, and certificates of completion for team learners. Works on phone, tablet, and computer.
This is awareness-level training only. It does not certify, qualify, or authorize anyone to perform work and does not by itself establish compliance. The employer is responsible for site-specific training, hands-on verification, and work authorization.